Profile picture

Stan M Yamashiro

Professor of Biomedical Engineering and Electrical and Computer Engineering

Education

  • Doctoral Degree, Biomedical Engineering, University of Southern California
  • Master's Degree, Biomedical Engineering, University of Southern California
  • Bachelor's Degree, Biomedical Engineering, University of Southern California

Biography

PhD Electrical Engineering. 1970 USC , Chairman : Fred Grodins

1971-74 Assistant Professor of Biomedical Engineering, University of Southern California. Teaching bio-instrumentation, medical electronics, and respiratory physiology. Research in peripheral circulation, mathematical models, and cardiopulmonary regulation.

1974-82 Associate Professor of Biomedical and Electrical Engineering, University of Southern California. Teaching medical electronics, signal processing, and laboratory computer applications. Research in dynamics of cardiopulmonary regulation.

1982-present Professor of Biomedical and Electrical Engineering, University of Southern California. Teaching cardiovascular and pulmonary physiology, instrumentation, and signal processing. Previous research in magnetocardiography, laser instrumentation, and gas exchange enhancement. Current research on developing mathematical models used in connection with training or use of Extracorporeal Membrane Oxygenators(ECMO).


Research Summary

Previous work has shown that breathing rate, airflow pattern shape, and the end-expiratory lung volume level can be predicted by an optimal control model based on minimum power expenditure. One prediction which is important to the control of breathing during exercise is a decrease in end-expiratory lung volume level which is graded according to the level of exercise. Such a decrease is consistently observed at the start of exercise and occurs in a feedforward or predictive manner. One of the consequences of a decreased lung volume is lengthening of the diaphragm, which according to the length-tension characteristics of skeletal muscle increases active tension. Lowering of lung volume requires activation of expiratory muscles, and this work is stored as elastic energy which can be recovered during the following inspiration. This constitutes a potential additional ventilatory drive independent of chemical factors. Based on a computer simulation study approximately half of the ventilatory drive during exercisecan be explained in this way. Animal experiments where phasic lung volume changes are artificially imposed do not support this possibility. However, this could be due to lung inflation reflexes which are strong in animals and known to be weak in humans.

An optimization hypothesis of respiratory control during exercise based on the minimization of a function reflecting both chemical and mechanical costs has been studied by others. Both additive and multiplicative controllers have been derived as optimal from similar cost functions. The purpose of a recent study was to explore the uniqueness of such predictions. Various formulations of controllers compatible with isocapnia were found to yield identical costs as controllers predicted to be optimal. It was concluded that controller predictions based on optimization theory are not unique. Optimization can occur with either an additive or multiplicative controller or any combination of the two which satisfies an isocapnic constraint. A general form of a combined additive-multiplicative controller was derived which was found to be compatible with previously reported experimental data collected during combined CO2 inhalation and exercise.

One of the difficulties which has hampered progress in research on physiological optimization is the tedium involved in the solution phase. In an attempt to solve this problem, a numerical procedure which allowed the convenient exploration of various optimization hypotheses of breathing pattern regulation was developed. The method was based on the calculus of variations and used a novel technique for the automatic evaluation of all required derivatives. Advantages of this approach included: exact calculation of all derivatives, parsimonious computer code, and speed of execution. By eliminating the need for hand derivation of derivatives, a major reduction was made in the tedium involved in exploring various optimization strategies. Examples were presented of determining the optimal breathing pattern characteristics for minimum work or force(pressure) required for breathing based on linear and noninear models of respiratory mechanics. The developed procedure can be used to predict the optimal volume-time trajectory and breathing frequency which minimizes a criterion function subject to constraints.

Multiple channel magnetocardiography is potentially useful for the study of the cardiac conduction system. However, normal atrial repolarization occurs simultaneously and obscures the interpretation of the net signal. Magnetocardiographic data in 4 normal subjects at rest and mild exercise were found to exhibit high spatial correlation during atrial activation. Based on measured channel-to-channel covariances, the atrial repolarization signals as measured in channels in the null zone of conduction system activity were used to estimate atrial repolarization in all channels. A linear prediction method was used which was based on the "kriging" estimator of geostatistical theory. Due to high spatial correlations in the limited thoracic region studied, predictions based on a single null channel were found to be adequate. Removal of the atrial component facilitates the beat-by-beat estimation of conduction system propagation times. These results support the feasibility of studying cardiac conduction system changes during rest and exercise using the multiple channel biomagnetometer.

Appointments
  • Alfred E. Mann Department of Biomedical Engineering
  • Ming Hsieh Department of Electrical and Computer Engineering - Systems
Office
  • DRB 152
  • Corwin D. Denney Research Center
  • 1042 Downey Way, Los Angeles, CA 90089
  • USC Mail Code: 1111
Contact Information
  • (213) 740-0336
  • syamash@usc.edu
Links